Tags: Sensorview Aeroflon CSVA3 DC-6GHz Microwave Cable
CSVA3 DC-6GHz Microwave Cable
Aeroflon ® DC – 6GHz Series Cable Assembly
Cable Part Number: CSVA3 (DC ~ 6GHz)
Construction
PartMaterialDiameter
1Center ConductorSilver Plated Copper [Stranded]Φ 19 / 0.225 [..
Available Options
Aeroflon ® DC – 6GHz Series Cable Assembly
Cable Part Number: CSVA3 (DC ~ 6GHz)
Construction
Part | Material | Diameter | |
1 | Center Conductor | Silver Plated Copper [Stranded] | Φ 19 / 0.225 [mm] Φ 19 / 0.0088 [inch] |
2 | Dielectric | Aeroflon ® [Extruded] | |
3 | 1st / 2nd Shield | Mylar tape & Copper wire | |
4 | Jacket | Ruggedized Aramid Yarn | Φ 5.80 ± 0.1 [mm] Φ 0.228 ± 0.003 [inch] |
Electrical & Mechanical Specification
Characteristic Impedance | 50 ± 1 Ω |
Operating Frequency | DC to 6 GHz |
Temperature | -50°C ∼ +135°C |
Velocity of Propagation | 77% nominal |
Minimum Bend Radius | 20 mm / 0.78 inch |
Weight [g/m] | 55.5 |
Shielding Effectiveness | < -90 dB |
Phase Stability vs. Flexure | 5° max. @6GHz |
Loss Stability vs. Flexure | Δ 0.05dB to 6GHz |
Available Connector | SMA / N |
Raw Cable Insertion Loss [ 25°C, at Sea Level ] | ||
Frequency | [dB/m] | [dB/FT] |
1 GHz | -0.36 | -0.108 |
2 GHz | -0.51 | -0.155 |
3 GHz | -0.63 | -0.192 |
4 GHz | -0.73 | -0.224 |
5 GHz | -0.83 | -0.252 |
6 GHz | -0.91 | -0.278 |
Average Power Rating [ CW, 25°C, at Sea Level ] | |
Frequency | [Watt] |
1 GHz | 505 |
2 GHz | 357 |
3 GHz | 292 |
4 GHz | 253 |
5 GHz | 226 |
6 GHz | 206 |